• 首页关于本刊投稿须知期刊订阅编委会期刊合作查询检索English
核电厂选址地震安全评价中的发震构造与能动断层
核电厂选址地震安全评价中的发震构造与能动断层
常向东*
国家环境保护总局核与辐射安全中心,北京100088
 [收稿日期]: 2006-07-10
摘要

根据核安全法规和导则,对核电厂选址地震安全评价中发震构造与能动断层的关系,以及发震构造与能动断层鉴定的时代问题进行了分析,并结合近年来核电厂选址评价中存在的问题,对发震构造与能动断层的评价方法进行了探讨。



Seismogenic Structure and Capable Fault in Seismic Safety Evaluation for Candidate Site of Nuclear Power Plant
Chang Xiangdong*
Nuclear and Radiation Safety Centre, State Environmental Protection Administration, Beijing 100088, China
Abstract

The relation and age identification about seismogenic structure and capable fault in seismic safety evaluation of NPP sitting are studied with accordance to the nuclear safety code and guidelines. In order to deal with some practical problems in the evaluation of nuclear power plant sitting of the nation in recent years, a conformable assessment technique about seismogenic structure and capable fault is proposed and discussed in this paper.